Simple handler supporting WLCSP By web_master01/13/201710/09/2021Product, Tester Interface products Characteristic Conditioning during design development Product confirmation at quality assurance department (failure analysis etc.) Various soft modes (same position repeat measurement mode · refill mode) Compact size and space saving Main specifications Products WLCSP, BGA, QFN, QFP etc. utility 単相AC100V、Max 10A, 50/60Hz DryAir 0.4MPa?0.7Mpa, 10NI/min780mm(W) x 800mm(D) x 500mm(H) Package sizeApplicable tray □1.6mm?□48mmEIAJ, JEDEC(135.8mm x 135.8mm) etc. Measurement environment Room temperature, high temperature (125 ° C) option * low temperature weight 60kg Number of measurementsNumber of classificationsType switching Take 1 pieceStandard 2 categories (maximum 6 categories)Change kit exchange time within 3 minutes option □ Change kit□ Ionizer□ 3 inch tray compatible, other tray compatible□ Same position / repeat measurement mode□ Tray refill mode□ mount indexresolution 2.8?3.8 sec/IC ※1)XY robot hand:50μmhandZ:30μm、ColletZ:50μm * 1) Please note that the index may vary depending on the target product.* Low temperature is handled with low-temperature dedicated handler All items LSI testing solution Tester Interface products High speed digital measurement, SI/PI Design solution Interface corresponding to various LSI testers Peripheral package IC test socket Desktop type DUT heating / cooling system Interface for DC parametric test Simple handler supporting WLCSP Manual · Prober α 100/150/200 Performance board for LSI tester Follow me! FacebooktwitterHatenaPocketCopy